Epro PR6423/012-121-CON041 Eddy Current Sensor
Epro PR6423/012-121-CON041 is an eddy current sensor, a complete non-contact eddy current monitoring system, compatible with Emerson AMS6500 (MMS6000) A6110 shaft vibration monitoring card, used for TSI protection of steam turbine units, centrifugal compressors, and gas turbines.

- PR6423/012-121 (probe+armored cable): Utilizing the eddy current effect, non-contact acquisition of changes in the gap between the rotating shaft and the probe, outputting weak high-frequency induction signals;
- CON041 (preamplifier): amplifies, linearizes, filters weak signals from the probe, and outputs standard gap voltage to the TSI card;
- The system can monitor radial shaft vibration, axial thrust displacement, shaft eccentricity, and oil film clearance in real time, trigger pre alarm/shutdown interlock when exceeding the limit, and comply with API 670 unit safety standards.
Detailed Specifications of PR6423/012-121 Probe
| Parameter Item | Technical Specification |
|---|---|
| Full Model Number | PR6423/012-121 |
| Probe Outer Diameter | φ8mm |
| Linear Measuring Range | Static ±1.0mm; Dynamic 0~500μm |
| Sensitivity | 8 V/mm |
| Mounting Thread | M10×1mm |
| Cable Sheath Structure | 012 = Metal armored cable, wear-resistant and anti-extrusion |
| Total Cable Length | 8m (121 = Bare wire end, matching screw terminal type CON041) |
| Standard Installation Air Gap | 1mm (Preamplifier output -12V midpoint voltage) |
| Compatible Shaft Material | 42CrMo4 carbon steel, ordinary magnetic metal shaft |
| Minimum Measured Shaft Diameter | ≥25mm |
| Probe Operating Temperature | -35℃ ~ +200℃ |
| Protection Rating | IP66 |
| Linearity Error | ≤1.0% FS |
| Explosion-proof Rating | Ex ib IIC T6 (Intrinsically Safe) |
| Compatible Preamplifier | CON041 only (Screw terminal type, not compatible with CON021 aviation plug type) |
Epro PR6423/012-121-CON041 Eddy Current Sensor

Detailed Specifications of CON041 Preamplifier
| Parameter Item | Technical Specification |
|---|---|
| Product Type | Eddy Current Signal Conversion Preamplifier |
| Power Supply Voltage | DC -23V ~ -32V (Standard -24V power supply) |
| Standard Linear Output Range | -4V ~ -20VDC (Midpoint reference voltage -12V) |
| Output Internal Resistance | 100kΩ |
| Frequency Response | 0 ~ 20000Hz (-3dB) |
| Rise Time | <15μs, fast dynamic response |
| Wiring Method | Screw crimp terminal (Compatible with 121 bare wire probe) |
| Hardware Protection | Automatic detection and protection for probe disconnection, short circuit, and power reverse connection |
| Operating Ambient Temperature | -30℃ ~ +100℃ (Installed in control room cabinet) |
| Installation Method | DIN rail snap-on installation |
| Protection Rating | IP20 |
| Weight | Approx. 60g |
| Compatible Monitoring Card | A6110 Shaft Relative Vibration/Displacement Monitoring Module |










There are no reviews yet.